strict management, quality first, quality service, and customer satisfaction

Test Equipment —Debulky water & Deoiling hydrocyclones

Short Description:

A test skid with one debulky water hydrocyclone unit installed of two hydrocyclone liners and two deoiling hydrocyclone units of each installed of a single liner. The three hydrocyclone units are designed in series to be used for testing the practical well stream with high water content at specific field conditions. With that test debulky water and deoilding hydrocyclone skid, it would be able to foresee the real result of water removal and produced water quality,  if the hydrocyclone liners to be used for the exact filed and operational conditions.


Product Detail

Product Tags

Technical parameters

Production Capacities & Properties

 

 

Min.

Normal.

Max.

Gross liquid Stream
(cu m/hr)

1.4

2.4

2.4

Inlet Oil content (%) ,max

2

15

50

Oil density (kg/m3)

800

820

850

Dynamic viscosity of oil (Pa.s)

-

Nor.

-

Water density (kg/m3)

-

1040

-

Fluids temperature (oC)

23

30

85

 

 

Inlet/Outlet Conditions  

Min.

Normal.

Max.

Operating pressure (kPag)

600

1000

1500

Operating temperature (oC)

23

30

85

Pressure drop of oil side (kPag)

<250

Water outlet pressure (kPag)

<150

<150

Produced oil specification (%)

To remove 50% or above water

Produced water specification (ppm)

< 40

Nozzle Schedule

Well Stream Inlet

2”

300# ANSI/FIG.1502

RFWN

Water Outlet

2”

150# ANSI/FIG.1502

RFWN

Oil Outlet

2”

150# ANSI/FIG.1502

RFWN

Instrumentation

Two rotary Flowmeters are installed at the water and oil outlets;

Six differential pressure gauges are equipped for inlet-oil outlet and inlet -water outlet of each hydrocyclone unit.  

SKID DIMENSION

1600mm (L) x 900mm (W) x 1600mm (H)

SKID WEIGHT

700 kg