Test Equipment —Debulky water & Deoiling hydrocyclones
Technical parameters
Production Capacities & Properties
|
Min. |
Normal. |
Max. |
|
Gross liquid Stream (cu m/hr) |
1.4 |
2.4 |
2.4 |
|
Inlet Oil content (%) ,max |
2 |
15 |
50 |
|
Oil density (kg/m3) |
800 |
820 |
850 |
|
Dynamic viscosity of oil (Pa.s) |
- |
Nor. |
- |
|
Water density (kg/m3) |
- |
1040 |
- |
|
Fluids temperature (oC) |
23 |
30 |
85 |
|
|
||||
Inlet/Outlet Conditions |
Min. |
Normal. |
Max. |
|
Operating pressure (kPag) |
600 |
1000 |
1500 |
|
Operating temperature (oC) |
23 |
30 |
85 |
|
Pressure drop of oil side (kPag) |
<250 |
|||
Water outlet pressure (kPag) |
<150 |
<150 |
||
Produced oil specification (%) |
To remove 50% or above water |
|||
Produced water specification (ppm) |
< 40 |
Nozzle Schedule
Well Stream Inlet |
2” |
300# ANSI/FIG.1502 |
RFWN |
Water Outlet |
2” |
150# ANSI/FIG.1502 |
RFWN |
Oil Outlet |
2” |
150# ANSI/FIG.1502 |
RFWN |
Instrumentation
Two rotary Flowmeters are installed at the water and oil outlets;
Six differential pressure gauges are equipped for inlet-oil outlet and inlet -water outlet of each hydrocyclone unit.
SKID DIMENSION
1600mm (L) x 900mm (W) x 1600mm (H)
SKID WEIGHT
700 kg